XH-CL-18 Low pressure centrifugal fan

Product Introduction

 XH-CL-18 type centrifugal fan is generally used for factories and large buildings ventilation. This type of centrifugal fan can be used to input and output gas, conveying air or other gas not self-ignite combusting, explosive, volatile, harmless to the human body, corrosive to the steel, and there shall be no viscous material in the gas, dust and hard particles contained in the gas shall not greater than 150 mg/m3,and gas temperature shall not exceed 80 ℃


Product Parameter

Drive Mode

Rotate Speed
 (r/min)

Operating Mode

Total Pressure
 (Pa)

Air Quantity
 (m3/h)

Required Power
 (KW)

Power
 (KW)

2.8

A

2900

1

970

1131

0.59

1.1

2

970

1319

0.65

3

961

1508

0.71

4

921

1696

0.74

5

853

1885

0.76

6

764

2073

0.77

7

657

2262

0.78

2.8

A

1450

1

245

565

0.07

0.55

2

245

660

0.08

3

235

754

0.09

4

225

848

0.09

5

215

942

0.10

6

186

1037

0.10

7

166

1131

0.11

3.15

A

2900

1

1245

1825

1.11

1.5

2

1245

2093

1.20

3

1225

2362

1.29

4

1176

2630

1.36

5

1098

2899

1.37

6

980

3167

1.38

7

853

3435

1.40

3.15

A

1450

1

313

912

0.14

0.55

2

313

1047

0.14

3

304

1181

0.14

4

294

1315

0.16

5

274

1449

0.17

6

245

1583

0.17

7

215

1718

0.18






 

Drive Mode

Rotate Speed
 (r/min)

Operating Mode

Total Pressure
 (Pa)

Air Quantity
 (m3/h)

Required Power
 (KW)

Power
 (KW)

4.5

A

2900

1

2657

5790

5.90

7.5

2

2628

6573

6.34

3

2569

7355

6.74

4

2461

8137

7.07

5

2294

8920

7.33

6

2069

9702

7.59

7

1833

10485

7.73

4.5

A

1450

1

666

2895

0.90

1.1

2

657

3286

0.97

3

637

3678

1.02

4

617

4069

1.08

5

568

4460

1.11

6

519

4851

1.16

7

460

5242

1.19

5

A

2900

1

3314

8050

10.12

15

2

3265

9123

10.86

3

3187

10197

11.53

4

3049

11270

12.06

5

2844

12343

12.49

6

2589

13416

13.01

7

2304

14490

13.25

5

A

1450

1

823

4025

1.42

2.2

2

813

4562

1.53

3

794

5098

1.63

4

764

5635

1.72

5

715

6172

1.78

6

647

6708

1.83

7

578

7245

1.89




 

Drive Mode

Rotate Speed
 (r/min)

Operating Mode

Total Pressure
 (Pa)

Air Quantity
 (m3/h)

Required Power
 (KW)

Power
 (KW)

6.3

D

1450

1

1323

8320

4.42

5.5

2

1304

9393

4.73

3

1274

10467

5.01

4

1216

11540

5.22

5

1137

12614

5.41

6

1039

13687

5.63

7

921

14761

5.69

6.3

D

960

1

578

5508

1.38

2.2

2

568

6219

1.47

3

558

6930

1.58

4

529

7641

1.63

5

500

8351

1.71

6

451

9062

1.75

7

402

9773

1.78

8

D

1450

1

2157

17585

14.4

18.5

2

2118

19783

15.4

3

2059

21982

16.2

4

1971

24179

16.9

5

1843

26378

17.4

6

1676

28576

18.0

7

1500

30774

18.3

8

D

960

1

941

11643

4.3

5.5

2

931

13098

4.7

3

902

14553

4.9

4

863

16009

5.1

5

804

17464

5.3

6

735

18919

5.5

7

657

20375

5.5



 

Drive Mode

Rotate Speed
 (r/min)

Operating Mode

Total Pressure
 (Pa)

Air Quantity
 (m3/h)

Required Power
 (KW)

Power
 (KW)

8

D

730

1

549

8853

2.1

3

2

539

9960

2.2

3

519

11067

2.3

4

500

12173

2.4

5

470

13280

2.5

6

421

14387

2.57

7

382

15403

2.7

10

D

1450

1

3442

35420

45.3

55

2

3363

39713

48.2

3

3265

44006

50.8

4

3108

48299

52.6

5

2922

52593

54.4

6

2687

56886

56.3

7

2422

61179

57.0

10

D

960

1

1510

23450

13.1

18.5

2

1480

26293

14.1

3

1431

29135

14.8

4

1363

31978

15.3

5

1274

34820

15.7

6

1176

37662

16.3

7

1059

40505

16.5

10

D

730

1

872

17832

5.8

7.5

2

853

19993

6.1

3

823

22155

6.5

4

784

24316

6.7

5

735

26478

6.9

6

676

28639

7.1

7

617

30801

7.3



Drive Mode

Rotate Speed
 (r/min)

Operating Mode

Total Pressure
 (Pa)

Air Quantity
 (m3/h)

Required Power
 (KW)

Power
 (KW)

12.5

D

960

1

2353

34.20

40.13

55

2

2304

36.40

42.71

3

2235

38.32

44.97

4

2128

39.69

46.58

5

2000

41.07

48.19

6

1833

42.33

49.67

7

1657

42.99

50.45

12.5

D

730

1

1363

15.05

17.66

22

2

1333

16.02

18.80

3

1294

16.87

19.80

4

1235

17.52

20.56

5

1157

18.06

21.19

6

1059

18.59

21.18

7

961

18.96

22.25




 Rotate Speed
 (r/min)

Operating Mode

Total Pressure
 (Pa)

Air Quantity
 (m3/h)

Required Power
 (KW)

Power
 (KW)

2240

1

3159

12852

16.09

22




 Rotate Speed
 (r/min)

Operating Mode

Total Pressure
 (Pa)

Air Quantity
 (m3/h)

Required Power
 (KW)

Power
 (KW)

2000

1

2510

11476

11.42

15

2

2481

12956

1227

3

2412

14437

12.94

4

2304

15917

13.49

5

2157

17398

14.00

6

1971

18879

14.56

7

1755

20359

14.78

1800

1

2040

10328

8.35

11

2

2010

11660

8.94

3

1951

12993

9.42

4

1863

14325

9.82

5

1745

15658

10.19

6

1588

16991

10.56

7

1422

18324

10.77

1600

1

1608

9180

5.85

7.5




 Rotate Speed
 (r/min)

Operating Mode

Total Pressure
 (Pa)

Air Quantity
 (m3/h)

Required Power
 (KW)

Power
 (KW)

1250

1

980

7172

2.91

4

2

970

8098

3.13

3

941

9024

3.29

4

902

9949

3.44

5

843

10874

3.57

6

764

11799

3.69

7

686

12724

3.77

1120

1

784

6426

2.26

3

2

774

255

2.42

3

755

8085

2.56

4

725

8913

2.69

5

676

9743

2.78

6

617

10572

2.88

7

549

11401

2.93

1000

1

627

5737

1.61

2.2

2

617

6478

1.73

3

607

7218

1.84

4

578

7958

1.91

5

539

8699

1.97

6

490

9439

2.05

7

441

10179

2.09

900

1

509

5164

1.27

1.5

2

500

5830

1.35

3

490

6497

1.44

4

470

7163

1.40

5

441

7829

1.46

6

402

8496

1.51

7

353

9162

1.51


operation

Before starting the fan, the following preparations should be made:
1Close the adjusting door.
2Check the clearance size of each part of the fan, whether there is scraping, friction and collision between rotating part and the fixed part.
3No one is allowed to stand near the impeller radius, coupling or pulley. The coupling or pulley shall be equipped with a safety cover, which shall be equipped by the user.
4Check whether the bearing lubricant is up to standard.
When the fan starts to normal speed, gradually open valve until the specified load. In the running process, bearing temperature shall not be higher than 40 ℃ and surface temperature shall not be higher than 70 ℃.
If it is found that the fan has violent vibration, impact, bearing temperature rises rapidly and other common phenomena, it must be stopped immediately to find out the reason.




http://www.xinhuablower.com/

Total0bar [View All]  Related Comments
 
More>other products

[ ProductsSearch ]  [ Send Fav ]  [ Share ]  [ Print ]  [ Send Report ]  [ Close ]

 
Home | Products | Suppliers | News | Tradeshow | Sitemap | Message | RSS Feed